Enterasys Networks Smart 2200 Manuale Utente Pagina 30

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 29
Installing the Device
3-4 Installation
Figure 3-1 Tabletop or Shelf Installation
3.3.2 Rackmount Installation
To install the 2H258-17R in a 19-inch rack, Enterasys Networks includes a strain-relief bracket for
cable management and an accessory kit containing the rackmount brackets, and mounting screws
to attach the rackmount brackets and strain-relief bracket.
Guidelines for the Rackmount Installation
The installation site must be within reach of the network cabling and meet the requirements listed
below:
An appropriate grounded power receptacle must be located within seven feet of the location.
Maintain a temperature of between 5°C (41°F) and 40°C (104°F) at the installation site with
fluctuations of less than 10°C (18°F) per hour.
CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the 2H258-17R.
WARNING: Before installing the 2H258-17R into a rack, ensure that the rack supports
the device(s) without compromising the stability of the rack. Otherwise, personal injury
and/or equipment damage may result.
3068-02
A = 15 cm (6 in)
B = 57 cm (22.5 in)
C = 53 cm (21 in)
C
B
A
D
D = 213 cm (7 ft)
RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX
123456 8910 151611 12 14137
2H258-17R
COM
PWR
CPU
RESET
FAST ETHERNET WORKGROUP SWITCH
Vedere la pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 61 62

Commenti su questo manuale

Nessun commento