APPENDIX A: EPIM SPECIFICATIONS
Page 28 BRIM-E6 USER’S GUIDE
power output at 25C equals -16.4 dBm. For a 4C temperature increase,
multiply the typical coefficient (-0.15 dBm) by four, and add the result to
typical output power (4 x -0.15 dBm + -16.4 dBm = -17.0 dBm)
Note: The above transmitter power levels and receive sensitivity levels
represent Peak Power Levels after optical overshoot. You must use a Peak
Power Meter to correctly compare the above values to those you measure
on any particular port. If you measure Power Levels with an Average
Parameter Typical
Transmit Power: -15.1 dBm
Transmit Budget: 14.4 dBm
Receive Sensitivity: -29.5 dBm
Maximum Receive
Power:
-6.99 dBm
Bit Error Rate: Better than
10